There Are Suggestions On Replacing a Single Point Load Cell Into a Scale

More from liheng huzhou

  • Several basic technologies are used in weighing transducers, such as pneumatic load cells (usually used in intrinsically safe applications)
    0 comments, 0 likes
  • An important aspect of choosing the correct shear beam load cell is to ensure that the load cell is properly sealed in the use environment
    0 comments, 0 likes
  • High-quality system of double shear beam load cell
    0 comments, 0 likes

More in Politics

  • Norton antivirus account login
    31 comments, 148,604 views
  • Liquidity Locking Made Easy
    11 comments, 83,679 views
  • Ang jili178 login ay nagdudulot sa iyo ng mga laro ng slot at karanasan sa laro ng soccer
    2 comments, 46,799 views

Related Blogs

  • Retail Fitout Company dedicated to exchanges
    0 comments, 0 likes
  • Studying Chances: Jobs in HELSINKI , Finland
    0 comments, 0 likes
  • Exploring the Advantages of 12V LiFePO4 Lithium Batteries for Off-Grid Solar Systems
    0 comments, 0 likes

Archives

Social Share

There Are Suggestions On Replacing a Single Point Load Cell Into a Scale

Posted By liheng huzhou     November 7, 2021    

Body

This process will differ depending on the scale or balance used, however the following will provide a general guideline on how to replace a single point load cell in a bench/ retail scale.

Ensure the power is switched off (both the mains and the scale).
Open the scale casing by carefully removing the screws in the designated areas.

Once the scale top has been removed you will see a variety of components. If replacing a load cell, it is common to find this fixed in position by an upper and lower metal frame. First, detach the load cell from the upper metal frame by unscrewing any central screws, then remove the upper metal frame by unscrewing the designated screws attached to the lower frame and carefully lifting.

Once the load cell has been exposed, detach the load cell by carefully disconnecting any wires. If the load cell, is screwed to the lower frame, you will also need to unscrew this prior to disconnecting any wires.

Once fully detached and removed, slot the new load cell onto the lower frame and reconnect any wires.

Carefully place the upper frame onto the load cell, ensuring the screw positions line up, and carefully screw in the central screw points to connect the load cell to the upper frame and then the exterior screws to fix the upper frame to the lower frame.

Once the load cell is secure, place the removed exterior casing back onto the scale and screw in to close.

We are one of the ball type load cell factory and welcome to your come and purchase!