There Are Suggestions On Replacing a Single Point Load Cell Into a Scale

More from liheng huzhou

  • Several basic technologies are used in weighing transducers, such as pneumatic load cells (usually used in intrinsically safe applications)
    0 commentaire , 0 comme
  • An important aspect of choosing the correct shear beam load cell is to ensure that the load cell is properly sealed in the use environment
    0 commentaire , 0 comme
  • High-quality system of double shear beam load cell
    0 commentaire , 0 comme

More in Politics

  • Norton antivirus account login
    32 commentaires, 157 837 vues
  • Liquidity Locking Made Easy
    13 commentaires, 84 457 vues
  • Boomerang Bet \u2013 Deutsches Casino mit Geringer Mindesteinzahlung
    0 commentaire , 51 864 vues

Related Blogs

  • Proven Benefits of Eating Fish In The Winter
    0 commentaire , 0 comme
  • Formatech offers cutting-edge preparation that can change your abilities.
    0 commentaire , 0 comme
  • \u062c\u0647\u0627\u0632 \u0627\u0644\u0628\u062e\u0627\u0631 \u0627\u0644\u0645\u0646\u0632\u0644\u064a: \u0634\u0631\u064a\u0643 \u0645\u0648\u062b\u0648\u0642 \u0644\u0644\u0639\u0646\u0627\u064a\u0629 \u0627\u0644\u0630\u0627\u062a\u064a\u0629 \u0645\u0646 \u062f\u064a\u0645\u0648\u0641\u0627 \u0645\u064a\u062f
    0 commentaire , 0 comme

Les archives

Partage Social

There Are Suggestions On Replacing a Single Point Load Cell Into a Scale

Posté par liheng huzhou     7 novembre 2021    

Corps

This process will differ depending on the scale or balance used, however the following will provide a general guideline on how to replace a single point load cell in a bench/ retail scale.

Ensure the power is switched off (both the mains and the scale).
Open the scale casing by carefully removing the screws in the designated areas.

Once the scale top has been removed you will see a variety of components. If replacing a load cell, it is common to find this fixed in position by an upper and lower metal frame. First, detach the load cell from the upper metal frame by unscrewing any central screws, then remove the upper metal frame by unscrewing the designated screws attached to the lower frame and carefully lifting.

Once the load cell has been exposed, detach the load cell by carefully disconnecting any wires. If the load cell, is screwed to the lower frame, you will also need to unscrew this prior to disconnecting any wires.

Once fully detached and removed, slot the new load cell onto the lower frame and reconnect any wires.

Carefully place the upper frame onto the load cell, ensuring the screw positions line up, and carefully screw in the central screw points to connect the load cell to the upper frame and then the exterior screws to fix the upper frame to the lower frame.

Once the load cell is secure, place the removed exterior casing back onto the scale and screw in to close.

We are one of the ball type load cell factory and welcome to your come and purchase!