\u3000BASIC TECHNICAL REQUIREMENTS FOR THE CONSTRUCTION OF ADSS OPTICAL CABLE
  • Mots clés - #ADSS Cable Clamp
    • Dernière mise à jour 20 juin 2022
    • 0 commentaire , 105 vues, 0 comme

More from foka foka

  • WHAT IS THE DIFFERENCE BETWEEN OPTICAL FIBER AND FIBER OPTIC CABLE?
    0 commentaire , 0 comme

More in Politics

  • Norton antivirus account login
    31 commentaires, 144 906 vues
  • Liquidity Locking Made Easy
    10 commentaires, 83 135 vues
  • Ang jili178 login ay nagdudulot sa iyo ng mga laro ng slot at karanasan sa laro ng soccer
    2 commentaires, 46 593 vues

Related Blogs

  • joker game
    0 commentaire , 0 comme
  • Why Choose a Trauma Cleaning Company?
    0 commentaire , 0 comme
  • Buy Psychedelics Canada Trend Is Making A Comeback
    0 commentaire , 0 comme

Les archives

Partage Social

 BASIC TECHNICAL REQUIREMENTS FOR THE CONSTRUCTION OF ADSS OPTICAL CABLE

Posté par foka foka     20 juin 2022    

Corps

The structure of ADSS fiber optic cable

  We are a manufacturer of communication equipment. Our products include ADSS Cable Clamp, etc. Let me share with Dahua the basic technical requirements for the construction of ADSS optical cable.

  ADSS is the abbreviation of All Dielectric Self-Supporting aerial optical cable in English, which means "all-dielectric self-supporting optical cable", and its structure does not contain any metal materials. ADSS fiber optic cable structure is currently divided into two categories: layer stranding type and central bundle tube type. Its structure diagram is as follows:

  Basic technical requirements for the construction of ADSS optical cable

  The location of the optical cable hanging point is selected to meet the safety distance regulations of "working on live line towers". (Minimum distance from live wire: 110KV≥1.5m, 220KV≥3.0m). According to the "Safety Regulations", the installation of ADSS optical cables on live lines can be regarded as work on live line towers. Therefore, the minimum distance between the operator's range of activities and the tools and materials they carry should not be less than the above-mentioned safe distance (110KV is not less than 1.5 meters, and 220KV is not less than 3.0 meters). Insulated non-polar ropes, insulated safety belts, and insulated tools must be used during construction. The wind force should not be greater than level five, and special personnel should be set up to monitor them. If the above conditions cannot be met, construction should be carried out according to live work or power outage. The glass fiber core in the ADSS optical cable is extremely fragile and will be damaged by stretching and lateral pressure. Therefore, the optical cable cannot be squeezed and stretched beyond the standard when the optical cable is installed. During construction, a tension pay-off machine should be used for tension pay-off, the traction tension should be stable, the traction tension should not exceed the index requirements, and the tension and lateral pressure during the erection of ADSS optical cables should not be too large (public account: power transmission and distribution lines).

commentaires

0 commentaire