How to operate the Arise web guiding system
    • Last updated April 3, 2023
    • 0 comments, 78 views, 0 likes

More from webguide Arise

  • What is the EPC Photoelectric Web Guiding System
    0 comments, 0 likes
  • Why Should Choose Web Guide System
    0 comments, 0 likes
  • Automatic web guide system from Arise
    0 comments, 0 likes

More in Politics

  • Norton antivirus account login
    31 comments, 143,579 views
  • Liquidity Locking Made Easy
    10 comments, 82,831 views
  • Ang jili178 login ay nagdudulot sa iyo ng mga laro ng slot at karanasan sa laro ng soccer
    2 comments, 46,378 views

Related Blogs

  • Magnetic Group Integrates AMOS for Enhanced MRO Services
    0 comments, 0 likes
  • Advantages of watching television shows online.
    0 comments, 0 likes
  • Home Features You Can't (Easily) Change and Why You Should Filter Results.
    0 comments, 0 likes

Archives

Social Share

How to operate the Arise web guiding system

Posted By webguide Arise     April 3, 2023    

Body

Arise all-in-one web guiding system can achieve multi-layer material alignment and there is no waste in the refueling process. The web guide system is an edge position controller for tracking the edge of the coil materials or printing lines for high-accuracy differential and swing. It is composed of large-scale industrial integrated circuits and has the advantages of high reliability and long service life.

web guiding certifications

Here are a few tips to operate the web guiding system after installation

Operation of the main interface

1. Install the rack and the all-in-one machine, plug the power and sensor plugs of the all-in-one into the corresponding sockets, and power on.

2. Enters the "manual" mode of the main interface and touch the "function menu" button. Then touch the "self-learning" button to enter the all-in-one self-adaptation and automatically return to "manual" mode.

3. Touch the "back to center" button, and then touch the "manual" button, respectively pressing the material of the same layer into the material according to the "material penetration diagram". Run the main machine for a few minutes to move the material for a period of time.

4. In the "manual" mode, adjust the sensor's position and the moving bracket in a large range and then adjust the rotary knob in a small range. (Adjust the position to the sensor offset display about 50%)

5. In the "automatic" mode, adjust the edges of the other layers of materials to coincide with the edges of the reference based on one layer, and the correction and debugging are completed.

main interface description of web guiding

Infrared sensor calibration

For some materials that are not easy to identify, the infrared sensor is required to achieve the best web guide effect.

Steps

1. Long press the "SET" button to make the sensor light flash (release the button after flashing)

2. Tighten the material and put it into the position of the sensor near the light lens (the material will completely cover the circular light-transmitting sheet). Then wait for 3 seconds and remove all the materials from the sensor.

3.Press the "SET" button until the light does not flash, and then release the button. The process of the calibration has been completed.

set botton of web guide infrared sensor

Common problems in the operation of the web guide system

1. The machine will swing to the limit alarm when it is switched to the "automatic" mode. (Confirm whether the correction polarity is correct and whether the sensor has a signal)

2. The speeds of the left and right swing are inconsistent in the "automatic" mode. (Check if the infrared sensor changes range from 0-100%)

3. When there are different materials in the "automatic" mode and the integrated machine does not swing, the infrared sensor is needed to calibrate the material.

If you have any question about the operation, please contact Arise web guiding.