MAIN METHODS AND SELECTION METHODS OF ELECTRICITY METER MEASUREMENT

More from zjsd121 zjsd121

  • ORIGIN OF ELECTROMAGNETIC PHENOMENON
    0 comments, 0 likes
  • PRECAUTIONS WHEN USING THE ENERGY METER
    0 comments, 0 likes

More in Politics

  • Norton antivirus account login
    27 comments, 127,946 views
  • Liquidity Locking Made Easy
    9 comments, 81,318 views
  • Ang jili178 login ay nagdudulot sa iyo ng mga laro ng slot at karanasan sa laro ng soccer
    2 comments, 45,499 views

Related Blogs

  • T\u00ecm hi\u1ec3u v\u1ec1 88BET - Nh\u00e0 c\u00e1i c\u00e1 c\u01b0\u1ee3c h\u00e0ng \u0111\u1ea7u v\u1edbi \u0111\u01b0\u1eddng link v\u00e0o 88 Bet
    0 comments, 0 likes
  • What is the cheapest day to fly on Frontier Airlines?
    0 comments, 0 likes
    $1.00
  • GTA Online: Some Players BANNED From Entering \uc548\uc804\ud55c\ub180\uc774\ud130 \uc548\uc804\ud55c\uc0ac\uc124\ud1a0\ud1a0! Rockstar Explains Why & More!? (GTA 5 Online)
    0 comments, 0 likes

Archives

Social Share

MAIN METHODS AND SELECTION METHODS OF ELECTRICITY METER MEASUREMENT

Posted By zjsd121 zjsd121     July 7, 2022    

Body

Three-phase Energy Meter Test Bench is one of our products. Let's share the main methods of energy meter measurement (three-phase four-wire, indirect, direct, single) and selection methods:

  1. In the process of selecting the electric energy meter, if the selection is not made in strict accordance with the requirements of the regulations, no calculation or analysis, the installed electric energy meter is either too large or too small, which will cause the electric energy meter to burn out. , too small will affect the accuracy of measurement.

  2. For low-voltage power supply, when the load current is 50A and below, the direct-connected electric energy meter should be used, and when the load current is above 50A, the connection type through the current transformer should be used. At the same time, an electric energy meter with an overload of 4 times or more should be used.

  3. What does the current 5(10)A, 10(20)A and 5(40)A on the nameplate of the electric energy meter mean? What's the difference?

  The current value before the brackets is called the calibration current, which is used to calculate the load base current value. The current in the brackets is called the rated maximum current, which is the maximum current value that can make the electric energy meter work normally for a long time, and the error and temperature rise fully meet the specified requirements.

  4. Use the electric energy meter and the transformer to measure together (current transformer, voltage transformer).

  The benefits of connecting the electric meter to the transformer: (1) The measuring range of the electric meter can be expanded. (2) The high voltage and high current are separated from the electric meter by the transformer, which ensures the safety of the electric meter, its secondary circuit and the staff.

  Three-phase Analog Power is also one of our products, welcome to visit our website!